F1 · DESIGNDesign
We start from your premises and how you use them, not from a catalogue.
MT/LT load balance, compressor and control selection, P&ID and wiring diagrams.
Industrial refrigeration · Automation · Supervision
We build custom refrigeration units, write the software that runs them and watch over them day and night. Below is one of our screens: try it.
Variable-speed multi-compressor units, PLC panels and software in Structured Text, Modbus RTU/TCP supervision with ColdCtrl gateway. Below, a ColdCtrl HMI in simulation.
24 h: -- · HACCP band -- · tolerance 30 min
Direct commands to the RS485 controller · the SET is written 5 s after the last tap
| Severity | Category | Alarm | Since | Duration |
|---|
| No | Category | Alarm | Start | End | Duration |
|---|
Alarm assistant: for every alarm the panel explains in plain words the probable cause, what to do right away and when to call the technician.
tap the chart to read the values · lanes below: defrost (grey), door (light blue), out of band (red)
Cooling energy LT / MT-- / -- kWh
Mean COP (output / input)--
Source: output power of the C1–C3 inverters read via Modbus and integrated by the supervisor into kWh (day, month, year). Demo values.
| Day | Signed by | Role | Time | Situation at the time of signing |
|---|
Sign HACCP check
--
Demo PIN: 2468
Enter your PIN
Alarm · alarm assistant
--
Probable cause
What to do right away
When to call the technician
Simulation in the same style as the installed ColdCtrl HMIs. Every 10 seconds the dispatcher moves a compressor between the LT and MT circuits, as in the hotel's refrigeration unit. The tabs at the bottom are the same as on the real panel: try ALARMS, HISTORY, ENERGY and the HACCP signature with PIN.
How we work
Whoever designs the plant also writes the software that runs it. Nothing gets lost between one supplier and another.
F1 · DESIGNWe start from your premises and how you use them, not from a catalogue.
MT/LT load balance, compressor and control selection, P&ID and wiring diagrams.
F2 · WORKSHOPWe assemble and wire everything in the workshop: it reaches the site already tested.
Frame, refrigeration circuit and panel assembled and bench-tested before shipping.

F3 · SOFTWAREWe test the software on a virtual plant before switching on the real one.
Structured Text on FREE Advance, hardware-in-the-loop tests on a plant model before every download.
F4 · SERVICEWe see the plant remotely and often solve problems without coming to you.
ColdCtrl gateway with VPN, HACCP history, alarms and remote action on set-points and defrosts.
◆ COLD CTRL World
Industry 4.0 readyCOLD CTRL is our line: refrigeration units designed, built and programmed in-house, and the ColdCtrl supervision platform that keeps them under control together with every load in the premises.

Safe by architecture. Redundant by design.


It's not a thermometer. It's a guardian.
Try the redundancy
Tap the compressors to simulate a fault. In a conventional unit the circuit would be left uncovered; COLD CTRL reassigns the remaining ones and keeps both circuits alive.
3 compressors available · MT and LT covered · 1 in reserve
Configurator
Every unit is born from a configuration and carries it in its name. Choose and watch the code build up.
Compact form:




ColdCtrl · cold chain supervision
A simulated plant with the ColdCtrl screens. Pick a load, open the cold room door and see what reaches the phone.
On the phone the customer sees the plant and receives the alerts; remote commands are reserved for the authorised technician.
Your smartphoneThis is where the notifications you would get on your phone, tablet or PC appear.
09:41
ColdCtrl · no alarms
Demo Restaurant
My plants
Plant sheets
Photos, figures and solutions are the real ones. We name clients only with their consent.
IMP-AB-01 · Flagship project
700 m² · 13 m · 4 °C · 65% RH
See the project →
IMP-MO-01 · Flagship project
2,534 m³ of water a year · −55% gas · 100% DHW from heat recovery
See the project →A cellar dug beneath a villa. Wine wants stable temperature and humidity together, summer and winter, and the machine had to sit a few metres from the house without being heard.
Existing air handling unit inside, new full-inverter condensing unit outside. Combined control of temperature and relative humidity with dew-point limit.



Breakfast, pool service, dinner: a hotel's cooling demand changes hour by hour. A rigid unit would almost always have run the wrong way.
Three variable-speed compressors with dynamic switching between the low- and medium-temperature circuits according to thermal load.



The new bar of a historic estate needed refrigeration for frozen goods, counters and display cases. There was no plant room: only a stone courtyard where guests stroll.
Enclosed outdoor unit with two independent circuits, LT −30 °C and MT, 20–90 Hz inverter-driven semi-hermetic compressors and floating condensing.



The kitchen of a resort in a medieval village needed refrigeration for cold rooms and counters. No machine was allowed to appear on the stone walls.
Enclosed two-compressor inverter condensing unit, LT −30 °C and MT −15 °C, with a remote housed condenser ducted DN300 into a flue and an EC plug fan with floating condensing.



So as not to disturb the neighbouring houses, the blast chiller’s condensing unit was far away: 60 metres of pipe and an 8-metre height difference. The previous compressor kept failing. We found out why and built the right machine.
Diagnosis: discharge temperature above 157 °C (evaporation −40 °C, condensing +45 °C, high superheat on the buried line) and insufficient oil return. Solution: two-stage semi-hermetic compressor with intermediate subcooler, R448A.



A demountable cold room for 4 Euro pallets, powered by the generator of the vehicle that carries it. Every watt counts here, and the control panel has to work both inside the cold and under the summer sun.
Variable-speed compressor, 20–95 Hz, on an inverter controlled via Modbus RS485, electronic expansion valve, adaptive hot-gas defrost (timed and on demand), R452A. Eliwell Advance PLC running our own software, with remote access over Modbus TCP.



Three insulated rooms for 1000-litre tanks of a product that must stay between +10 and +25 °C all year round. Each room has its own temperature and can heat while another one cools.
One inverter condensing unit, 30–65 Hz, with R513A (non-flammable refrigerant, class A1), floating evaporation and heaters in the evaporators for heating mode. Eliwell Advance PLC with a touch HMI and 4 access levels; variables are exported over Modbus TCP to the plant’s energy management system.



Official partner since 2024
With Benelli S.r.l. di Follonica we work as official partners in designing and building the refrigeration systems serving their professional kitchens: hotels, restaurants and cafés in Tuscany.
Project atlas · in progress
About us
Engineering, workshop and software under one roof. We are small on purpose: the person who answers the phone is the one who designed your plant.
Innovative Automation is founded.
The first industrial refrigeration units.
MicroWater patent.
Multi-purpose heat pumps.
Plant for a large production facility.
Official partner of Benelli S.r.l. for professional kitchen refrigeration systems.
Hotel in Forte dei Marmi, wine cellar in Punta Ala, ColdCtrl Rel. 2.0.
Contact
Even if it's old, mixed or undocumented. That's the work we like best.
✓ Thank you!
We have received your request and will contact you as a matter of priority.